\nApplication<\/strong><\/td>\nGeneral electrical measurements<\/td>\n | HVAC applications<\/td>\n<\/tr>\n | \nVoltage Measurement<\/strong><\/td>\nUp to 600V AC\/DC<\/td>\n | Up to 600V AC\/DC<\/td>\n<\/tr>\n | \nCurrent Measurement<\/strong><\/td>\nUp to 10A AC\/DC (20A for 30 seconds)<\/td>\n | Up to 600 \u00b5A AC\/DC<\/td>\n<\/tr>\n | \nResistance<\/strong><\/td>\nUp to 40 M\u03a9<\/td>\n | Up to 40 M\u03a9<\/td>\n<\/tr>\n | \nCapacitance<\/strong><\/td>\nUp to 10,000 \u00b5F<\/td>\n | Up to 10,000 \u00b5F<\/td>\n<\/tr>\n | \nFrequency<\/strong><\/td>\nUp to 50 kHz<\/td>\n | Up to 50 kHz<\/td>\n<\/tr>\n | \nTemperature<\/strong><\/td>\nNo<\/td>\n | Yes, -40\u00b0C to +400\u00b0C (-40\u00b0F to +752\u00b0F)<\/td>\n<\/tr>\n | \nMicroamps Measurement<\/strong><\/td>\nNo<\/td>\n | Yes, for HVAC flame sensors<\/td>\n<\/tr>\n | \nLoZ (Low Impedance)<\/strong><\/td>\nNo<\/td>\n | Yes, helps prevent false readings due to ghost voltage<\/td>\n<\/tr>\n | \nDisplay<\/strong><\/td>\n6000 counts, backlit<\/td>\n | 6000 counts, backlit<\/td>\n<\/tr>\n | \nSafety Rating<\/strong><\/td>\nCAT III 600V<\/td>\n | CAT III 600V<\/td>\n<\/tr>\n | \nWarranty<\/strong><\/td>\n3 years<\/td>\n | 3 years<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\nConclusion<\/strong><\/h3>\nIf you are looking for a quality and an affordable multimeter to perform a wide range of functions, then you can\u2019t go wrong with Fluke 115 multimeter. Aside from the fact that Fluke 115 price is reasonable, it is a durable, compact, portable, and accurate unit that performs a wide range of functions and it is very easy to use. However, this gadget has shortcomings of its own such as it cannot measure milliamps and microamps, which limits it to electrical instead of electronic work. Generally, the Fluke 115 is a wonderful unit for beginners and DIY enthusiasts, though professional technicians can as well as utilize it to carry out basic functions. I hope that this Fluke 115 Review will really help you find the right multimeter for you.<\/p>\n FAQ<\/h2>\nQuestion: Does this unit come with a calibration certificate?<\/strong> \nAnswer:<\/strong> In most cases, companies do not issue this type of certificate. Nevertheless, you can request a certificate from Fluke for an extra charge.<\/p>\nQuestion: Can I measure temperature utilizing this multimeter? <\/strong> \nAnswer:<\/strong> No, it is not possible. It doesn\u2019t matter if you buy a separate probe or not, this digital multimeter will not measure temperature.<\/p>\nQuestion: Is this product made in the USA?<\/strong> \nAnswer:<\/strong> No, it is not. The Fluke 115 digital multimeter is designed and not made in the USA. All the same, Fluke has manufacturing plants around the world and all of them produce high-quality products.<\/p>\nStill, have a question after reading this Fluke 115 Review? Comment below.<\/p>\n","protected":false},"excerpt":{"rendered":" The Fluke 115 digital multimeter is a nice tool for both home and industrial use. It can also be used […]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":1590,"menu_order":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"pgc_meta":"","_lmt_disableupdate":"","_lmt_disable":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"jetpack_post_was_ever_published":false,"footnotes":""},"yst_prominent_words":[12945,12733,17630,3027,12744,12730,12732,3711,12738,13259,17629,17627,5545,17632,12743,12801,12742,8572,12731],"class_list":["post-11616","page","type-page","status-publish","hentry"],"pgc_meta":"","jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/P9auoK-31m","rttpg_featured_image_url":null,"rttpg_author":{"display_name":"Christopher Joseph","author_link":"https:\/\/totalguide.org\/author\/ttlgde\/"},"rttpg_comment":5,"rttpg_category":" 115<\/a>115 digital multimeter<\/a>115 true-rms digital multimeter<\/a>digital multimeter<\/a>fluke<\/a>fluke 115<\/a>fluke 115 digital<\/a>fluke 115 digital multimeter<\/a>fluke 115 multimeter<\/a>fluke 115 review<\/a>fluke 115 true-rms digital<\/a>fluke 115 true-rms digital multimeter<\/a>multimeter<\/a>read this fluke 115<\/a>true rms<\/a>true rms multimeter<\/a>true-rms digital multimeter<\/a>unit<\/a>wide range of functions<\/a>","rttpg_excerpt":"The Fluke 115 digital multimeter is a nice tool for both home and industrial use. It can also be used […]","_links":{"self":[{"href":"https:\/\/totalguide.org\/wp-json\/wp\/v2\/pages\/11616","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/totalguide.org\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/totalguide.org\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/totalguide.org\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/totalguide.org\/wp-json\/wp\/v2\/comments?post=11616"}],"version-history":[{"count":7,"href":"https:\/\/totalguide.org\/wp-json\/wp\/v2\/pages\/11616\/revisions"}],"predecessor-version":[{"id":15918,"href":"https:\/\/totalguide.org\/wp-json\/wp\/v2\/pages\/11616\/revisions\/15918"}],"up":[{"embeddable":true,"href":"https:\/\/totalguide.org\/wp-json\/wp\/v2\/pages\/1590"}],"wp:attachment":[{"href":"https:\/\/totalguide.org\/wp-json\/wp\/v2\/media?parent=11616"}],"wp:term":[{"taxonomy":"yst_prominent_words","embeddable":true,"href":"https:\/\/totalguide.org\/wp-json\/wp\/v2\/yst_prominent_words?post=11616"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}} | | | | | | | | | | | | |